WhatsApp_Image_2020-06-24_at_11.34.18_AM__1_-removebg-preview.pngWhatsApp_Image_2020-06-24_at_11.34.18_AM__3_-removebg-preview.pngWhatsApp_Image_2020-06-24_at_11.34.18_AM-removebg-preview.pngWhatsApp_Image_2020-06-24_at_11.34.19_AM__2_-removebg-preview.pngWhatsApp_Image_2020-06-24_at_11-removebg-preview (3).png

PQN Series PQN-7435 Formaldehyde gas detector is designed to detect Formaldehyde in the industrial areas.

With ATEX / IECEx, SIL2 certifications, EN 60079-29: 1 performance approval, and high ingress protection class, it has proved its suitability for harsh environmental conditions.

The Pellistor sensor employed PQN-7435 provides excellent output in the 0-100%LEL range.

Connectivity
• Sensor: Pellistor in PQN provides accurate and reliable results.
• Modbus: It is easy to integrate PQN detectors into SCADA systems easily via open source Modbus RS485(RTU) codes
• Outputs: Different devices can be operated/controlled at the same time thanks to the 4-20mA analog, Modbus RS485 and Relay outputs
• Relay Contacts: PQ-3R+ relay module integrated PQN Series detectors can manage other equipment or can be linked to firefighting panels.
 
Maintenance and Installation
• Sensor Replacement: Allows sensor replacement with pre-calibrated sensor head to provide easy maintenance.
• Installation: Designed for either wall or ceiling mounting applications
• Entry: 1/2''NPT - 3/4''NPT - 3xM20 cable entries
• Remote Control: Detector status can be monitored Prosense Gas Monitoring software remotely.
 
Robust and Reliable
• Body: Aluminium die-cast body and SS316 stainless steel sensor head superb performance under harsh environmental conditions with IP65 protection class.
• Protection: Sunshield and waterproof caps are available for use in extreme conditions.

Sensor Technology Pellistor
Output Signal 4-20mA Analog and RS485 Modbus RTU
Sensor Warm-Up 60sec
Response Time(T90) <25sec
Accuracy %±1
Operating Temperature -40°C ~ +70°C
Humidity 0~ 100%RH Non-Condensing
Input Min 10VDC - Max 32VDC - Nominal 24VDC
Event Logging Records alarm, fault and maintenance events up to 250 logs
Power Consumption Max. 4W
Relay Outputs 2 Alarms (Programmable) and 1 Fault (All relays are NO/NC adjustable)
IP Rating IP65 / IP66
Junction Box Epoxy Painted Die-Cast Aluminum / 316 Stainless Steel
Sensor Head 316L Stainless Steel
Dimensions/Weight 196,96x145,99x112mm / 2100gr
ATEX Marking II 2G Ex db IIC T6 Gb
II 2G Ex mb db IIC T6 Gb
I M2 Ex db I Mb
Hazardous Class Zone 1 - Zone 2 - M2
Certificates ExVeritas 18 ATEX 0371X
IECEx EXV 18.0021X
FTZU 18 ATEX 0086
IEP12 ATEX 6118X
SIL2
Standards IEC EN 60079-0
IEC EN 60079-1
IEC EN 60079-18
IEC EN 60079-29-1
  1. PQN Series Datasheet

    PQN Series Datasheet

PQ-3R+ Provides 2xAlarms, 1xFault Relay Contacts PQ-3R+
P-IP66 Stainless Series IP66 Adapter P-IP66
P-ASU Prosense Sampling Unit P-ASU
PQD-SS PQD SS316L Stainless Series Enclosure PQD-SS
P-GTA Celling Mount Collecting Cone P-GTA
PK-KEP Prosense Calibration Cap PK-KEP